BasicLine BL 510 Isolated Standard Signal Conditioner
This compact signal isolator provides straightforward galvanic isolation and signal conversion in standard applications.
Facts
- Straightforward galvanic isolation in standard applications
- Conversion of one standard signal to another one, as required
- Galvanic 3-port isolation prevents measurement errors
- 6-mm housing requires minimal space
- Long service life, in particular due to its low power dissipation
- Calibrated range selection without complicated manual adjustments
- Easy configuration using DIP switches accessible from the outside
- CE compliant and UL approved
- 3-year warranty
- Perfect price-performance ratio
Input 0 … 20 mA
4 … 20 mA
0 … 10 VAccuracy < 0.3 % full scale Test voltage 0.51 kV AC Working voltage 150 V AC/DC Power supply 24 V DC Further functions Calibrated range selection -
BasicLine BL590/591 Universal Transducer
Designed to measure currents and voltages with up to 500 V
Facts
- Calibrated range selection
- 10 selectable input ranges and unipolar as well as bipolar output signals
- Universal power supply for 24 V DC supply or 100 … 230 V AC mains supply
- Only 17.5 mm wide modular housing with comprehensive functionality
- Passive output for direct connection to a supplying PLC
- Monitor output for non-disruptive measurement of the output current by connecting a multimeter or permanently connecting an isolated display unit
- Galvanic 3-port isolation for undistorted transmission of the measuring signals or damages
- Highest reliability
- Optimum price/perfomance ratio
- 3 year warranty
-
BasicLine BL570 Universal Isolator
The “multitalent” among the isolators: Every range between ±20 mV and ±200 V DC can be individually adjusted. Over 400 ranges are factory-calibrated.\
Facts
- Universal DC voltage and current measurement
- 480 switchable calibrated ranges without readjustment
- Voltage range anywhere between ± 20 mV and ± 200 V, individually adjustable
- Currents up to 100 mA are measured directly; higher currents via external shunt resistor
- Adjustable range offset
- Universal power adapter for 24 V DC supply or 100 … 230 V mains supply
- 3-port isolation protects against incorrect measurements or damage
- Maximum reliability
- CE compliant and UL approved
- 3-year warranty
- Perfect price-performance ratio
Input 0 … 20 mV/200 V, 0 … 100 μA/100 mA unipolar/bipolar Accuracy < 0.25 % full scale Test voltage 1.5 kV AC Working voltage 300 V AC/DC Power supply 24 V DC/100 … 230 V AC Further functions Calibrated range selection -
ProLine P 52000 VPD Voltage Presence Detector
Railway and Industrial Application Solution for Monitoring Voltages from 50 – 4200 V AC/DC
ProLine P 52000 VPD detects the presence of voltage. The input signal is compared to a threshold value and the resulting binary information is galvanically isolated and transmitted to the output circuit. When the input voltage exceeds the set threshold value, a solid state relay opens, signaling the presence of voltage at the input. The signal of the solid state relay can control a hardware relay, for example, or be fed into a safety device or controller. The signal levels are based on type 1, EN 61131-2 PLC signal inputs. The threshold value applies regardless of the sign of the input voltage’s absolute value. In other words, the solid state relay will be triggered as soon as the positive threshold value is exceeded or the input voltage is below the negative threshold. 10 default threshold values can be selected using the rotary switch on the front of the device. Units with user-defined values are also available. Standard/Directive | Industry Standards EN 50155, RIA12/1984 Broad-range power supply 24 … 230 V DC/AC, stable during brownouts – Class S2 EN 45545-2a) Fire protection (HL 3) EN 50155 Use on rolling stock EN 50155, EN 50125-1, EN EN 50125-2 Temperature class TX (-40 … +85 °C) and altitude class AX (2000 m or 4000 m AMSL) EN 50123-1 Use in traction power substations EN 61709 Reliability EN 61140 Protection against electric shock EN 61373 Resistant to vibration and mechanical shock (railway applications) EN 50121-1, EN 50121-3-2; EN 61326-1 EMC for railway applications and industrial applications EN 50153 Protective measures against electrical hazards (contact protection through protective covers; housing IP protection: IP54 high-voltage side, IP33 low-voltage side) EN 50124-1, EN 50123-1, EN 50178 Isolation coordination for railway and industry
-
VariTrans P 41000 High Voltage Transducer
The VariTrans P 41000 isolation amplifiers have been specially conceived for measurements of bipolar voltages from millivolts to volts. They reliably isolate high potentials at the input circuit. The isolating distances are designed to withstand permanent voltages up to 3600 V AC/DC and fast transients up to 20 kV. Protection against electric shock is achieved through protective separation according to EN 61140 between input and output and power supply. Specially designed for current measurements using a shunt resistor.